Wagner SprayTech GM 2000 EACF User Manual Page 1

Browse online or download User Manual for Paint Sprayer Wagner SprayTech GM 2000 EACF. Wagner SprayTech GM 2000 EACF User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Operating Manual
GM 2000 EACR - EN
GM 2000 EACF - EN
0179 887 GBEdition 03/98
Electrostatic AirCoat Spraygun,
with flat or round jet tips
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - GM 2000 EACF - EN

Operating ManualGM 2000 EACR - ENGM 2000 EACF - EN0179 887 GBEdition 03/98Electrostatic AirCoat Spraygun, with flat or round jet tips

Page 2

1.5 CE Conformity1.5.1 Short explanationCE = Communauté Européenne:Products identified with the CE mark have been manufactured and checked accordingto

Page 3

2. DESCRIPTION2.1 Scope of supplyPart No. Quantity Description0179 018 1 Electrostatic AirCoat spray gun GM 2000 EAC R, with round jet tip R 15 .or017

Page 4

● The trigger can be used toactivate, one after the other, thevarious functions of the spraygun.An increase in the tensionneeded to pull the trigger b

Page 5 - "Note"

2.3.2 AirCoat round jet process In the AirCoat process, high pressure of 30 to 150 bar is used to atomize the material.The AirCoat air at 0 to 2.5 ba

Page 6

2.3.4 Electrostatic effectThe spray gun produces an electrostatic field by means of the high voltage electrode.As a result, the particles of paint, wh

Page 7

3. PREPARATION BEFORE STARTING WORKCautionThe operating instructions and the safety regulations for the additional systemcomponents used must be read

Page 8

Empty pageGM 2000 EAC - EN3.2

Page 9

4. STARTING WORK, AND HANDLINGCaution See SAFETY REGULATIONS in chapter 1.4.1 Preparation● Locking of spray gun! Turn locking nut clockwise until sto

Page 10 - GM 2000 EAC - EN

4.4 Cleaning of clogged round jet tips1. By means of tip spanner (A),loosen tip insert (B) by a half turn.2. Remove tip spanner and briefly pulltrig

Page 11 - Attention

4.7 Replacing AirCoat flat jet tips1. Switch off control unit.2. Relieve spray gun and systempressure!3. Lock spray gun. Turn locking screwclockwise u

Page 13

Empty pageGM 2000 EAC - EN4.4

Page 14

5. MAINTENANCECaution See SAFETY REGULATIONS in chapter 1.AttentionThe spray gun and the system must be cleaned every day. Use only the cleaning sol-v

Page 15

5.2 Dissassembly of AirCoat nozzle body (round jet)1. Unscrew tip nut.2. Remove nozzle body (3) withspanner (B)3. Unscrew tip insert (1) with tipspan

Page 16

5.4 Adjustment of the valve rod sealIn case paint leaks at the valve rodnear the trigger: 1. Pull trigger and throughlyclean paint channel with solven

Page 17 - Caution

5.6 Exchange of paint channel● if the round jet nozzle is fitted1. Unscrew tip nut (1).2. Unscrew tip body (2) with universal spanner.3. Unscrew seal

Page 18

6. TROUBLE SHOOTING AND SOLUTIONSGM 2000 EAC - EN6.1ProblemInsufficient materialoutputPoor spray patternLeaking air valvePoor wrap round orelectrostat

Page 19

Empty pageGM 2000 EAC - EN6.2

Page 20

7. ACCESSORIES7.1 Round jet tip inserts The round jet tips are especially suited to spray pipes, profiles andcomplex workpieces.Part-No. Marking Volu

Page 21

7.2 AirCoat flat tipsAirCoat flat jet tips are used for fast, economic application of material toflat workpieces.Part Marking size Spraying Volume Je

Page 22 - Note (round jet EAC)

7.3 Filter (standard)7.4 Long filter housing and and filters7.5 Hoses and fittings7.6 Special toolsGM 2000 EAC - EN7.3Description MeshPart No.for 1 pc

Page 23

CONTENTSParagraph Chapter.Page1 INTRODUCTION 1.11.1 Using the manual 1.11.2 SAFETY REGULATIONS 1.21.3 PTB Conformity certification 1.41.4 Product li

Page 24

Empty pageGM 2000 EAC - EN7.4

Page 25

8. SPARE PARTS CATALOGUE8.1 How to order spare parts?Always supply the following information to ensure delivery of the right spare part:Part No., des

Page 26

8.3 Spare parts listGM 2000 EAC - EN8.2Item Part No. K Quantity Description2 0179 354 1 Positioning bush3 9900 962 1 Countersunk screw M3x12 4 0179

Page 27

3938404142484937505551525354GM 2000 EAC - EN8.3

Page 28

Empty pageGM 2000 EAC - EN8.4

Page 30

England / United KingdomWAGNER Spraytech (UK) Lt. Telephone ++44 / (0)1295/ 265 353Haslemere Way Telefax ++44 / (0)1295/ 269 861Tramway Industri

Page 31

CONTENTSParagraph Chapter.Page7 ACCESSORIES 7.17.1 Round jet tip inserts 7.17.2 AirCoat flat tips 7.27.3 Filter (standard) 7.37.4 Long filter housing

Page 32

1. INTRODUCTIONThis operating manual contains information and instruction for the operation, repairand maintenance of the spray gun.This equipment can

Page 33

1.2 SAFETY REGULATIONSThe safety requirements for electrostatic hand spraying equipement are laiddown in the following documents: (Germany)1) ZH 1/250

Page 34

1.2.4 Protective breathing masksAlthough the E-Static AirCoat spraying procedure produces very little mist, it isnot completely mist free. There are,

Page 35

1.3 PTB Conformity certificationGM 2000 EAC - EN1.4

Page 36

1.4 Product liability and guaranteeWarranty12 months / 6 months for multi-shift operationThis equipment is covered by the following manufacturing warr

Comments to this Manuals

No comments